C-SCOPE XD Bedienerhandbuch Seite 1

Stöbern Sie online oder laden Sie Bedienerhandbuch nach Elektrowerkzeuge C-SCOPE XD herunter. C-SCOPE XD Instruction manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 20
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
CS1220XD - RAPID GET YOU GOING INSTRUCTIONS
Assemble and adjust for length (Twist surplus lead around stem).
Insert batteries.
Set the MODE SELECT (bottom right) to METER AUDIO DISC.
Set POWER ON/OFF TUNE (top left) to ON.
Set SENSITIVITY fully anticlockwise to the BATTERY CHECK position. The meter will
indicate in the right hand green sector if the batteries are OK.
Set SENSITIVITY to mid position (12 o’clock).
With the search head 1-2 cm from the ground, press and hold the RETUNE button (lower
mid) and adjust the TUNE control until a tone is just
heard. Release the RETUNE button.
The CS1220XD is now ready for use. If the tone drifts from the threshold position press the
RETUNE button to reset the level.
You are now in a PROGRAMMED MODE. The other modes require more detailed
explanation found in the following pages.
IF A PROBLEM IS ENCOUNTERED REFER TO THE FULL INSTRUCTIONS.
1
Seitenansicht 0
1 2 3 4 5 6 ... 19 20

Inhaltsverzeichnis

Seite 1

CS1220XD - RAPID GET YOU GOING INSTRUCTIONS Assemble and adjust for length (Twist surplus lead around stem). Insert batteries. Set the MODE S

Seite 2 - CONTENTS:

Pre-programmed Modes There are two pre-programmed modes provided: i) Meter Audio Disc ii) Meter Disc Meter Audio Disc This is the recommended mode

Seite 3 - Controls C-Scope CS1220XD

Tune the detector with the search head 1-2 cm above the ground. Sweep the detector in an arc, ensuring the head is level and as close to the ground

Seite 4 - ASSEMBLY

to get maximum depth without problems associated with keeping the search head a constant height above the ground surface. When a target object has b

Seite 5 - BATTERY CHECK

GENERAL HINTS Beach Mode On a wet salt beach it is best to reduce the SENSITIVITY to mid range and operate in a Discrimination Mode all the time (i.

Seite 6 - CONTROLS AND WHAT THEY DO

Detection Range Your CS1220XD is a top performance detector but adverse soil conditions can significantly reduce the depth of detection. Detection

Seite 7

(ii) To ‘focus’ the target signal still further raise the search head, retuning if necessary, and pass the search head over the object until only

Seite 8

CHARGING BATTERIES A battery charge socket is provided for use with the C-Scope battery charger (see Accessories) and is located under the protectiv

Seite 9 - METHODS OF OPERATION

against you finding it. On the other hand, if you pegged out the area scientifically and searched slowly and thoroughly, the odds of finding the rin

Seite 10

is well to note here that the operator should not rush. This is one of the most common mistakes made by detector users. If you rush, you will not ade

Seite 11

2. Respect the Country Code. Do not leave gates open when crossing fields, and do not damage crops or frighten animals. 3. Do not leave a mess. It

Seite 12

CONTENTS: PAGE INTRODUCTION 4 ASSEMBLY 4 BATTERIES 4 BATTERY CHECK 5 CONTROLS AND WHAT THEY DO 6 METHODS OF OPERATION 9 GENERAL HINTS 13 AC

Seite 13 - GENERAL HINTS

20 TROUBLESHOOTING (a) Check the condition of batteries under load using the meter. (See Battery Check Procedure). (b) Check that the search head

Seite 14

Controls C-Scope CS1220XD ABCDEFG A Battery Compartment B Upper Stem & Handle Grips C Din Plug & Socket D Stem Connecting Nut E C

Seite 15

INTRODUCTION To protect your investment complete both sections of the enclosed guarantee card and return to C-Scope. This is particularly important

Seite 16 - CHARGING BATTERIES

holder which is located in the battery compartment. To fit new batteries first check the power switch on the unit is switched to OFF. Then loosen th

Seite 17 - SWEEPING TECHNIQUE

CONTROLS AND WHAT THEY DO 1. On/Off Tune 5. Retune button 2. Sensitivity/Battery Check 6. Ground Push Select button 3.

Seite 18

Function Switch (3) This rotary switch selects the Pre-programmed modes Meter Audio Disc and Meter Disc or the Manual Control modes GD1 and GD2. Wh

Seite 19 - CARE OF YOUR DETECTOR

manufacture at the optimum level. The level is the same in switch positions GD1 and GD2. Discriminate D1 & D2 The Discriminate circuit can be se

Seite 20 - TROUBLESHOOTING

Ground (6) This push button is operative in Manual Control Modes GD1 and GD2 only. It sets the detector for operation in most types of ground condit

Kommentare zu diesen Handbüchern

Keine Kommentare